Home ProductsHV Power Cable

150mm2 500mm2 630mm2 Single Core 110kV HV Power Cable

150mm2 500mm2 630mm2 Single Core 110kV HV Power Cable

    • 150mm2 500mm2 630mm2 Single Core 110kV HV Power Cable
    • 150mm2 500mm2 630mm2 Single Core 110kV HV Power Cable
    • 150mm2 500mm2 630mm2 Single Core 110kV HV Power Cable
    • 150mm2 500mm2 630mm2 Single Core 110kV HV Power Cable
    • 150mm2 500mm2 630mm2 Single Core 110kV HV Power Cable
  • 150mm2 500mm2 630mm2 Single Core 110kV HV Power Cable

    Product Details:

    Place of Origin: china
    Brand Name: OEM
    Certification: ISO/RoHS/CE

    Payment & Shipping Terms:

    Minimum Order Quantity: 200 meters
    Price: Negotiable
    Packaging Details: wooden drum
    Delivery Time: 5-15day
    Payment Terms: L/C, T/T
    Supply Ability: 50000meters per week
    Contact Now
    Detailed Product Description
    Conductor: Class 2 Copper Or Aluminum Conductor Conductor Screen: Extruded Semi-conductive XLPE
    Insulation: XLPE Insulation Screen: Extruded Semi-conductive XLPE
    Separator: Water Swellable Tape Screen: Copper Wire Screen, With A Counter Helix Of Copper Tape
    Sheath: HDPE
    High Light:

    150mm2 HV Power Cable

    ,

    110kV 630mm2 HV Power Cable

    ,

    110kV 500mm2 hv electrical cables

    150mm2 500mm2 630mm2 Single Core 110kV HV Power Cable

     

     

     

    APPLICATION:

     

    The high voltage power cables contained within this datasheet are suitable for the primary distribution of power up to a maximum network voltage of 110kV. Suitable for locations where mechanical protection is afforded by other means and where the additional protection of a moisture barrier has been determined not to be necessary, see 2XS(FL)2Y and A2XS(FL)2Y. The cables are triple extruded using proprietary materials on modern catenary line equipment to the latest IEC standards. Waterblocking tape options ensure that should the cable be damaged, repair lengths and associated works are kept to a minimum. The cables are provided as standard with

    a high density polyethylene sheath, chosen to give the best compromise between abrasion resistance and flexibility to ensure installation confidence. The range can be customized to meet specific project demands should the need arise

     

    CONSTRUCTION:
    Conductor
    Class 2 copper or aluminum conductor, compacted or segment
    strand Milliken to BS EN 60228 (previously BS 6360)
    Conductor Screen
    Extruded semi-conductive XLPE (Cross-Linked Polyethylene)
    Insulation
    XLPE (Cross-Linked Polyethylene)
    Insulation Screen
    Extruded semi-conductive XLPE (Cross-Linked Polyethylene)
    Separator
    Water swellable semi-conductive tape
    Screen
    Copper wire screen, with a counter helix of copper tape
    Separator
    Water swellable tape
    Sheath
    HDPE (High Density Polyethylene)

     

     

    150mm2 500mm2 630mm2 Single Core 110kV HV Power Cable 0

     

    DIMENSIONS
    2XS(F)2Y Copper Conductor

    NO. OF
    CORES
    NOMINAL
    CROSS
    SECTIONAL
    AREA
    mm²
    ELECTRICAL
    PROTECTION
    mm2
    NOMINAL
    DIAMETER OF
    CONDUCTOR
    mm
    NOMINAL
    THICKNESS OF
    INSULATION
    mm
    NOMINAL
    DIAMETER
    OVER
    INSULATION
    mm
    NOMINAL
    OVERALL
    DIAMETER
    mm
    NOMINAL
    WEIGHT
    kg/km
    MINIMUM
    BENDING
    RADIUS
    (FIXED)
    mm
    MAXIMAL
    FORCE OF
    DRAGGING
    (CONDUCTOR
    PULLING)
    kN
    1
    1
    1
    1
    1
    1
    1
    1
    150
    185
    240
    300
    400
    500
    630
    800
    95
    95
    95
    95
    95
    95
    95
    95
    14.1
    15.7
    18
    20.3
    23
    26.5
    30.3
    36.9
    18
    17
    16
    15
    15
    15
    15
    15
    54.9
    54.5
    54.8
    55.1
    57.6
    61.3
    64.5
    71.8
    64.5
    64.1
    64.4
    64.7
    67.4
    71.3
    74.8
    82.6
    4910
    5145
    5614
    6085
    7075
    8185
    9740
    11869
    970
    960
    970
    1000
    1010
    1070
    1200
    1240
    7.5
    9.2
    12
    15
    20
    25
    31.5
    40


    A2XS(F)2Y Aluminium Conductor

    NO. OF
    CORES
    NOMINAL
    CROSS
    SECTIONAL
    AREA
    mm²
    ELECTRICAL
    PROTECTION
    mm2
    NOMINAL
    DIAMETER OF
    CONDUCTOR
    mm
    NOMINAL
    THICKNESS OF
    INSULATION
    mm
    NOMINAL
    DIAMETER
    OVER
    INSULATION
    mm
    NOMINAL
    OVERALL
    DIAMETER
    mm
    NOMINAL
    WEIGHT
    kg/km
    MINIMUM
    BENDING
    RADIUS
    (FIXED)
    mm
    MAXIMAL
    FORCE OF
    DRAGGING
    (CONDUCTOR
    PULLING)
    kN
    1
    1
    1
    1
    1
    1
    1
    1
    1
    1
    150
    185
    240
    300
    400
    500
    630
    800
    1000
    1200*
    95
    95
    95
    95
    95
    95
    95
    95
    95
    95
    14.1
    15.7
    18
    20.3
    23
    26.5
    30.3
    36.9
    37.9
    44
    18
    17
    16
    15
    15
    15
    15
    15
    15
    15
    54.9
    54.5
    54.8
    55.1
    57.6
    61.3
    64.5
    71.8
    72.8
    78
    64.5
    64.1
    64.4
    64.7
    67.4
    71.3
    74.8
    82.6
    84
    90
    3995
    4026
    4156
    4263
    4746
    5287
    5908
    6925
    7409
    8010
    970
    960
    970
    1000
    1010
    1070
    1200
    1240
    1260
    1350
    4.5
    5.5
    7.2
    9
    12
    15
    18.9
    24
    30
    36

     

    CONDUCTOR

    Class 2 Stranded Conductors for Single Core and Multi-Core Cables

    NOMINAL CROSS
    SECTIONAL AREA
    mm²
    MINIMUM NO. OF WIRES IN CONDUCTOR MAXIMUM RESISTANCE OF CONDUCTOR AT 20ºC
    Circular Circular Compacted Annealed Copper Conductor Aluminum or Aluminum
    Alloy Conductor
    ohms/km
    Cu Al Cu Al Plain Wires
    ohms/km

    150
    185
    240
    300
    400
    500
    630
    800

    1000
    1200*

    37
    37
    37
    61
    61
    61
    91
    91

    91
    /

    37
    37
    37
    61
    61
    61
    91
    91

    91
    /

    18
    30
    34
    34
    53
    53
    53
    53

    53
    /

    15
    30
    30
    30
    53
    53
    53
    53

    53
    /

    0.124
    0.0991
    0.0754
    0.0601
    0.047
    0.0366
    0.0283
    0.0221

    0.0176
    /

    0.206
    0.164
    0.125
    0.1
    0.0778
    0.0605
    0.0469
    0.0367

    0.0291
    0.0247

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

    ELECTRICAL CHARACTERISTICS

    1= cross-bonding of grounding
    2= both ends grounded

    CONDUCTOR TYPE COPPER CONDUCTOR ALUMINIUM CONDUCTOR
    INSTALLATION GROUND AIR GROUND AIR
    METHOD OF
    INSTALLATION
    Flat Spaced Trefoil Flat Spaced Trefoil Flat Spaced Trefoil Flat Spaced Trefoil
    METHOD OF
    EARTHING
    1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2
    NOMINAL CROSS
    SECTIONAL AREA
    mm²
    CURRENT RATINGS
    Amps
    150
    185
    240
    300
    400
    500
    630
    800
    1000
    1200*
    435
    490
    570
    640
    720
    825
    940
    1055
    -
    -
    406
    448
    505
    535
    595
    650
    705
    755
    -
    -
    410
    465
    540
    610
    690
    785
    890
    1000
    -
    -
    406
    453
    519
    580
    650
    730
    810
    885
    -
    -
    551
    630
    740
    805
    915
    1060
    1235
    1415
    -
    -
    515
    574
    659
    685
    775
    860
    950
    1040
    -
    -
    478
    546
    645
    710
    820
    945
    1085
    1235
    -
    -
    473
    538
    628
    685
    785
    895
    1010
    1130
    -
    -
    335
    380
    445
    495
    565
    645
    740
    845
    950
    1025
    325
    363
    416
    445
    500
    555
    610
    665
    720
    755
    320
    360
    420
    475
    540
    620
    710
    805
    900
    970
    320
    358
    416
    460
    525
    595
    670
    745
    820
    870
    431
    494
    583
    625
    715
    835
    975
    1130
    1295
    1420
    415
    465
    541
    565
    640
    725
    820
    910
    1005
    1070
    373
    425
    504
    550
    640
    745
    865
    995
    1135
    1235
    373
    423
    499
    540
    625
    720
    830
    940
    1055
    114

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

    DE-RATING FACTORS

    AMBIENT TEMPERATURE 10ºC 15ºC 20ºC 25ºC 30ºC 35ºC 40ºC 45ºC 50ºC 55ºC 60ºC 65ºC 70ºC
    In Ground 1.07 1.04 1.00 0.96 0.93 0.89 0.85 0.80 0.76 0.71 0.65 0.60 0.53
    In Air 1.15 1.12 1.08 1.04 1.00 0.96 0.91 0.87 0.82 0.76 0.71 0.65 0.58

    Contact Details
    Beijing Silk Road Enterprise Management Services Co.,LTD
    Send your inquiry directly to us (0 / 3000)

    Other Products